Skip to content

Search…

Search
Close this search box.
  • About Us
    • Company Overview
    • Global Sales Network
    • Manufacturing Facilities
    • Why LEOCH?
    • Sustainability
    • Careers
  • Solutions
    • Network Solutions
      • Telecom/CATV
      • Uninterruptible Power Supply
      • Utility & Switchgear
      • Energy Storage
      • Fire & Security
      • Medical Equipment
      • Emergency Lighting
    • Transportation Solutions
      • Automotive
      • Commercial Heavy Duty
      • Powersports
      • Lawn/Garden
      • Marine
    • Motive Solutions
      • Golf & Utility Vehicles
      • Floor Care
      • Material Handling
      • Aerial Work Platform
      • Mobility
  • Resources
    • FAQs
    • Certifications
    • Safety Data Sheets
    • Terminal & Torque Information
    • Recycling
    • Battery Finder
    • Battery Sizer
  • News & Events
  • Contact Us
Menu
  • About Us
    • Company Overview
    • Global Sales Network
    • Manufacturing Facilities
    • Why LEOCH?
    • Sustainability
    • Careers
  • Solutions
    • Network Solutions
      • Telecom/CATV
      • Uninterruptible Power Supply
      • Utility & Switchgear
      • Energy Storage
      • Fire & Security
      • Medical Equipment
      • Emergency Lighting
    • Transportation Solutions
      • Automotive
      • Commercial Heavy Duty
      • Powersports
      • Lawn/Garden
      • Marine
    • Motive Solutions
      • Golf & Utility Vehicles
      • Floor Care
      • Material Handling
      • Aerial Work Platform
      • Mobility
  • Resources
    • FAQs
    • Certifications
    • Safety Data Sheets
    • Terminal & Torque Information
    • Recycling
    • Battery Finder
    • Battery Sizer
  • News & Events
  • Contact Us

Utility & Switchgear Solutions

REQUEST QUOTE

OPzS Series

Flooded Tubular Batteries

LEOCH® OPzS Series, Flooded Tubular batteries have been specifically engineered for critical standby applications, offering a wide operating temperature of -4°F to 131°F (-20°C to 55°C) and long design life of 20 years. LEOCH® OPzS Series utilize SAN transparent containers for easy electrolyte level monitoring (Optional PC Flame-Retardant cover to UL94V-0). Standard 1.240 Specific Gravity, with optional 1.215 SG.

Features
Specifications
Applications
Documents
Features
  • Capacity 99.2 to 2965.6AH at 8-HR rate
  • Wide operating temperature: -4°F to 131°F (-20°C to 55°C)
  • SAN transparent container (Optional PC Flame-Retardant material to UL94V-0) 
  • Small footprint – easily installed into standard or seismic racks
  • Designed for Critical Standby Applications – 20 year design life
  • Standard 1.240 Specific Gravity, with optional 1.215 SG
  • Virgin lead plates and copper alloy terminal inserts offer lower internal resistance
  • 100% initial capacity
  • IEC 60896-11 certified
Specifications
LEOCH® MODEL NUMBER VOLTAGE (V) RATED CAPACITY (AH)* DIMENSIONS WEIGHT TERMINAL TYPE SPECIFICATION SHEETS
8HR 10HR LENGTH WIDTH HEIGHT TOTAL HEIGHT
1.75V/CELL 1.80V/CELL IN MM IN MM IN MM IN MM LBS KG
3OPzS150 2 148 150 4.06 103 8.11 206 13.98 355 16.14 410 33.7 15.3 M10 Download
4OPzS200 2 197.6 200 4.06 103 8.11 206 13.98 355 16.14 410 38.4 17.4 M10 Download
5OPzS250 2 247.2 250 4.88 124 8.11 206 13.98 355 16.14 410 45.0 20.4 M10 Download
6OPzS300 2 296.8 300 5.71 145 8.11 206 13.98 355 16.14 410 52.5 23.8 M10 Download
5OPzS350 2 345.6 350 4.88 124 8.11 206 18.54 471 20.71 526 62.4 28.3 M10 Download
6OPzS420 2 415.2 420 5.71 145 8.11 206 18.54 471 20.71 526 72.1 32.7 M10 Download
7OPzS490 2 484 490 6.54 166 8.11 206 18.54 471 20.71 526 83.8 38 M10 Download
6OPzS600 2 592.8 600 5.71 145 8.11 206 25.43 646 27.60 701 100.1 45.4 M10 Download
10OPzS1000 2 988.8 1000 9.17 233 8.27 210 25.43 646 27.60 701 170.6 77.4 M10 Download
12OPzS1200 2 1186.4 1200 10.83 275 8.27 210 25.43 646 27.60 701 202.2 91.7 M10 Download
12OPzS1500 2 1482.4 1500 10.83 275 8.27 210 31.34 796 33.50 851 250.9 113.8 M10 Download
24OPzS3000 2 2965.6 3000 22.68 576 8.35 212 30.39 772 32.56 827 495.6 224.8 M10 Download
  • ©LEOCH. ALL RIGHTS RESERVED. SUBJECT TO REVISIONS WITHOUT PRIOR NOTICE.
  • *RATED CAPACITY – @ 77°F (25°C)
Applications
  • Central Office Telecommunications
  • Critical Utility Switchgear and Control Power
  • Distributed Energy
  • Solar & Wind Energy Storage
  • Railway Signaling
  • Long Life Standby Power 
Documents

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

Download

ENGLISH

Download

Download

Download

Request a Quote

Have unique footprints and need a custom quote, contact us today to learn more about our industry leading solutions.
CONTACT US

Battery Sizing

Size your next critical power application with LEOCH® Batteries

Calculate
LEOCH® Battery Corporation
20322 Valencia Circle Lake Forest, CA 92630
Phone: +1 (949) 588-5853
Email: sales@leoch.us

Follow Us

  • Site Map
  • Privacy Policy
  • Terms & Conditions
  • ISO 9000 CERTIFIED
  • Copyright © 2024 LEOCH Battery Corporation.
    All Rights Reserved.

About Us

  • Company Overview
  • Global Sales Network
  • Manufacturing Facilities
  • Why LEOCH?

Resources

  • FAQs
  • Certifications
  • Safety Data Sheets
  • Terminal & Torque Information
  • Recycling
  • Battery Finder
  • Battery Sizer
  • Sustainability
  • News & Events
  • Careers

Solutions

  • Network Solutions
  • Telecom/CATV
  • Uninterruptible Power Supply
  • Utility & Switchgear
  • Energy Storage
  • Fire & Security
  • Medical Equipment
  • Emergency Lighting
  • Motive Solutions
  • Golf & Utility Vehicles
  • Floor Care
  • Material Handling
  • Aerial Work Platform (AWP)
  • Mobility
  • Transportation Solutions
  • Automotive
  • Commercial Heavy Duty
  • Powersports
  • Lawn/Garden
  • Marine
  • Copyright © 2024 LEOCH Battery Corporation.
    All Rights Reserved.
Manage Cookie Consent
This site uses cookies to offer you a better browsing experience. By continuing to navigate this site or by clicking accept, you consent to the use of cookies on your device as described in our privacy policy.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}

This site uses cookies to personalize your experience. By continuing to navigate this site or by clicking approve, you consent to the use of cookies on your device as described in our privacy policy.

Powered by  GDPR Cookie Compliance
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Cookie Policy

More information about our Cookie Policy